Airlift pump

Diagram of an airlift pump
An airlift pump, powered by compressed air, raises fluid by entraining gas to reduce its density. 1. Air supply. 2. Liquid supply. 3. Air inlet port. 4. Air supply line. 5. Air port. 6. Air outlet. 7. Fluid intake. 8. Riser tube. 9. Air liquid mixture. 10. Pump outlet. L:Liquid, usually wastewater. LL:Liquid level. V:Vessel G:Gravel or solids.

An Airlift pump is a pump that has low suction and moderate discharge of liquid and entrained solids. The pump injects compressed air at the bottom of the discharge pipe which is immersed in the liquid. The compressed air mixes with the liquid causing the air-water mixture to be less dense than the rest of the liquid around it and therefore is displaced upwards through the discharge pipe by the surrounding liquid of higher density. Solids may be entrained in the flow and if small enough to fit through the pipe, will be discharged with the rest of the flow at a shallower depth or above the surface. Airlift pumps are widely used in Aquaculture to pump, circulate and aerate water in closed, recirculating systems and ponds.[1] Other applications include dredging, underwater archaeology, salvage operations and collection of scientific specimens.

Principle

The only energy required is provided by compressed air. This air is usually compressed by a compressor or a blower. The air is injected in the lower part of a pipe that transports a liquid. By buoyancy the air, which has a lower density than the liquid, rises quickly. By fluid pressure, the liquid is taken in the ascendant air flow and moves in the same direction as the air. The calculation of the volume flow of the liquid is possible thanks to the physics of two-phase flow.


Utilization

Airlift pumps are often used in deep dirty wells where sand would quickly abrade mechanical parts. (The compressor is on the surface and no mechanical parts are needed in the well). However airlift wells must be much deeper than the water table to allow for submergence. Air is generally pumped at least as deep under the water as the water is to be lifted. (If the water table is 50 ft below, the air should be pumped 100 feet deep).

It is also sometimes used in part of the process on a wastewater treatment plant if a small head is required (typically around 1 foot head).


Airlifts are used to collect fauna samples from sediment.[2] Airlifts can oversample zooplankton and meiofauna but undersample animals that exhibit an escape response.[2]

Inventor

The first airlift pump is considered to be invented by the German engineer Carl Emanuel Löscher (de), who lived in the second part of the eighteenth century. He discovered the airlift pump in 1797.

Advantages and disadvantages

The following paragraph exposes the advantages and disadvantages of the airlift pump compared to other pumping techniques.

Advantages

  • The pump is very reliable. The very simple principle is a clear advantage. Only air with a higher pressure than the liquid is required.
  • The liquid is not in contact with any mechanical elements. Therefore, neither the pump can be abraded (which is important for sandwater wells), neither the contents in the pipe can be abraded (which is important for archeological research in the sea)
  • Act as a water aerator and can in some configurations lift stagnant bottom water to the surface (of water tanks).
  • Since there are no restrictive pump parts, solids up to 70% of the pipe diameter can be reliably pumped.

Disadvantages

  • cost: while in some specific case the operational cost can be interesting, most of the time, the quantity of air to compress is high compared to the liquid flow required.[3] · [4] · .
  • Conventional airlift pumps have a flow rate that is very limited. The pump is either on or off. It is very difficult to get a wide range of proportional flow control by varying the volume of compressed air. This is a dramatic disadvantage in some parts of a small wastewater treatment plant, such as the aerator.[5]
  • The suction is limited.
  • This pumping system is suitable only if the head is relatively low. If you want to obtain a high head, you have to choose a conventional pumping system.
  • Because of the principle, a lot of air remains in the liquid. In certain case, this can be problematic, as, for example, in a waste water treatment plant, before an anaerobic basin.

Design improvements

Diagram of a geyser pump
A geyser pump, an improved airlift pump, powered by compressed air, raises fluid by forcing rising bubbles to displace fluid. 50. Air supply. 52. Air inlet port. 58. Liquid supply. 60,62. air supply lines. 64. upper end of air tank 86. 66,82. Air ports. 70. Upper air inlet of u-shaped elbow 74. 76 Air outlet. 84. Fluid intake. 65. Riser tube. 88. Displaced liquid. 90. Pump outlet. L:Liquid, usually wastewater. LL:Liquid level. VVV:Vessel G:Gravel or solids

A recent (2007) variant called the "geyser pump" can pump with greater suction and less air. It also pumps proportionally to the air flow, permitting use in processes that require varying controlled flows. It arranges to store up the air, and release it in large bubbles that seal to the lift pipe, raising slugs of fluid.[6]

See also

Notes and references

  1. ^ http://www.airlift.eu/
  2. ^ a b Cahoon, LB; Lindquist, DG; Clavijo, IE; Tronzo, CR (1992). "Sampling small invertebrates at the sediment-water interface". In: Cahoon, LB. (ed.) Proceedings of the American Academy of Underwater Sciences Twelfth Annual Scientific Diving Symposium "Diving for Science 1992". Held September 24–27, 1992 at the University of North Carolina at Wilmington, Wilmington, NC.  
  3. ^ air quantity calculation PDF (1.86 MB)
  4. ^ airlift basic calculation - dead link, 15 April 2013
  5. ^ New Pump Technology May Improve Small Flows, WVU NCSFC Clearinghouse Accessed 2011-3-21
  6. ^ Patent Application number: 11/654,448, January 17, 2007, Inventor: Masao Kondo
  • Airlift calculation by Sanitaire (pdf document) these links are no longer valid
This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 


Copyright © World Library Foundation. All rights reserved. eBooks from Project Gutenberg are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.