Lucens reactor

Switzerland Nuclear power plants ()
 Active plants
 Closed plants

The Lucens reactor at Lucens, Vaud, Switzerland, was a small pilot nuclear reactor destroyed by an accident in 1969.

In 1962 the construction of a Swiss-designed pilot nuclear power plant began. The heavy-water moderated, carbon dioxide gas-cooled, reactor was built in an underground cavern[1] and produced 30 megawatts of heat (which was used to generate 8.3 megawatts of electricity).[2] It became critical in 1966 and the plant was decommissioned in 1988.[3] It was fueled by 0.96% enriched uranium alloyed with chromium cased in magnesium alloy (magnesium with 0.6% zirconium) inserted into a graphite matrix. Carbon dioxide gas was pumped into the top of the channels at 6.28 MPa and 223 °C and exited the channels at a pressure of 5.79 MPa and at a temperature of 378 °C.

It was intended to operate until the end of 1969, but during a startup on January 21, 1969, it suffered a loss-of-coolant accident, leading to a partial core meltdown and massive radioactive contamination of the cavern, which was then sealed.

The accident was caused by water condensation forming on some of the magnesium alloy fuel element components during shutdown and corroding them. The corrosion products from this accumulated in some of the fuel channels. One of the 73 vertical fuel channels was sufficiently blocked by it to impede the flow of carbon dioxide coolant so that the magnesium alloy cladding melted and further blocked the channel. The increase in temperature and exposure of the uranium metal fuel to the coolant eventually caused the fuel to catch fire in the carbon dioxide coolant atmosphere. The pressure tube surrounding the fuel channel split because of overheating and bowing of the burning fuel assembly, and the carbon dioxide coolant leaked out of the reactor.[4][5]

No irradiation of workers or the population occurred, though the cavern containing the reactor was seriously contaminated. The cavern was decontaminated and the reactor dismantled over the next few years.

References

  1. ^ Summary of Swiss nuclear reactors, SAPIERR Support Action: Pilot Initiative for European Regional Repositories
  2. ^ Swiss nuclear power, French Nuclear Energy Agency
  3. ^ "On-site disposal as a decommissioning strategy" (PDF). International Atomic Energy Agency. November 1999. p. 67. Retrieved 6 January 2013. 
  4. ^ Description of events, Nuclear tourist
  5. ^ Heavy water reactors: Status and projected development, IAEA, 2002

See also

External links

  • Maps of Nuclear Power Reactors: Switzerland
  • Major Nuclear Power Plant Accidents

This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 


Copyright © World Library Foundation. All rights reserved. eBooks from Project Gutenberg are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.