World Library  
Flag as Inappropriate
Email this Article

Thermally Advantaged Chassis

Article Id: WHEBN0005564780
Reproduction Date:

Title: Thermally Advantaged Chassis  
Author: World Heritage Encyclopedia
Language: English
Subject: Computer enclosure, List of computer standards, Computer hardware cooling, TAC, Computer case
Collection: Computer Enclosure, Computer Hardware Cooling
Publisher: World Heritage Encyclopedia
Publication
Date:
 

Thermally Advantaged Chassis

A Thermally Advantaged Chassis (TAC) is a computer enclosure that complies with the Thermally Advantaged Chassis specifications created by Intel. It is capable of maintaining an internal ambient temperature below 38 degrees Celsius when functioning with Intel's Pentium 4 and Celeron D processors based on 90 nm process technology, and an ambient temperature below 39 degrees Celsius when using a Pentium D processor. Intel maintains that using a thermally advantaged chassis is the absolute minimum requirement for using Pentium 4 (Prescott), Pentium D, and Celeron D, processors.

Contents

  • Overview 1
  • Airflow pattern 2
    • System fans 2.1
    • Side-panel venting 2.2
  • External links 3

Overview

In the 1.1 version, the TAC design is intended to disallow internal temperature rises of more than 3 degrees Celsius, and provide the processor with a cooler environment to work in. Its main feature is a Chassis Air Guide that directs room temperature air directly in the path of the CPU fan and heat sink. The chassis air guide is a passive cooling system, and relies completely on internal system fans to guide the air.

Airflow pattern

As with most computers, the rear fan and power supply fan exhaust, moving hot air away from the computer. This causes a slight depressurization inside the chassis, and requires all other openings to become intake vents. Airflow from the front of the chassis moves around the Chassis Air Guide, allowing the processor fan to only draw air from outside the chassis, providing more effective cooling.

System fans

The rear chassis exhaust fan is required to be at least 92-mm or larger, providing a minimum of 55 CFM in free air. The processor is required to have an active cooling system, consisting of a fan and heat sink.

Side-panel venting

The side-panel is required to have an add-in card vent, which provides room temperature air to the add-in cards. High-performance graphics cards will benefit from the lower temperature air.

External links

  • Thermally Advantaged Tested Chassis List(subscription required)
  • Chassis Air Guide v1.1 (September 2003)
  • Standard (Japanese).


This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 


Copyright © World Library Foundation. All rights reserved. eBooks from Project Gutenberg are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.