A cross-tube boiler was the most common form of small vertical boiler. They were widely used, in the age of steam, as a small donkey boiler, for the independent power of winches, steam cranes etc.[1][2][3]

Steam crane, with cross-tube boiler

The boiler has the advantage of simple robust construction, in particular requiring little regular maintenance. It is relatively inefficient, which was not a serious drawback to the purposes for which it was used. However it was also of limited heating surface, thus limiting its sustained output power, compared to other boiler designs. For that reason it was rarely used when power was required continuously, such as for locomotives. However as the boiler is of relatively large internal volume relative to its power, this acts as a transient reserve of steam. Applications such as cranes only require steam intermittently, allowing the boiler to recover pressure between lifts.

Construction

A sectioned view of a cross-tube boiler. The section shows a single vertical flue or fire-tube, with two large water-tubes across the firebox beneath this.

The boiler consists of a cylindrical vertical external shell, with a large firebox inside this, filling perhaps half of the total height. A single large vertical flue or uptake leads to an external chimney. Some boilers use vertical rod stays between the firebox crown and top of the boiler shell.

The main evaporative surface is provided by a pair of large water-filled cross-tubes across this firebox and directly exposed to the radiant heat of the fire. As these tubes are large in diameter they remain mostly filled with water, rather than filling with steam,[notes 1] and so the boiler is not classed amongst the usual water-tube boilers. These tubes are horizontal,[1] or slightly inclined[2] so as to encourage circulation in a single direction without turbulence.

As usual, there is a manhole in the upper part of the shell for internal access and inspection. The boiler may be distinguished externally from other types of vertical boiler by the additional presence of two smaller handholes, in line with the end of each tube and used for internal cleaning.

Plate and tube wastage in service

Unlike fire-tube boilers, the boiler was not designed for regular maintenance such as the re-tubing and replacement of wasted tubes as a minor event. Any pitting or grooving that did develop would be a major matter to repair, requiring the replacement of plates. In practice, the boilers were robustly constructed and operating at fairly low pressure, and so minor wastage was acceptable.

The most likely location for wastage developing was around the uptake flue, at the operating water level where activity and erosion was most severe.[2] This actually represented one of the boiler's main advantages, compared to vertical boilers with multiple fire-tubes. Erosion there took place on the thin-walled tubes and was a perennial problem.

Improved circulation

Circulation in boilers is largely due to the thermosyphon effect, which is encouraged by the vertical rise of the water-tubes. As the simple cross-tube boiler has near-horizontal tubes, circulation is poor. To improve this, designs such as the Clarke Chapman 'Tyne' boiler used steeply angled main tubes and small vertical tubes at the sides. This improved circulation, although it made washout difficult.

Notes

  1. ^ Large diameter gives a low ratio of heating surface to water volume, thus a low boiling rate.

References

  1. ^ a b  
  2. ^ a b c Milton, J. H. (1961) [1953]. Marine Steam Boilers (2nd ed.). Newnes. pp. 70–77. 
  3. ^ Stokers Manual ((1912 edition) ed.). Admiralty, via HMSO, via Eyre & Spottiswoode. 1901. 

External links

  • "New boiler is manufactured for Clyde puffer, VIC 32". Save the Puffer. 2006. 
This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 


Copyright © World Library Foundation. All rights reserved. eBooks from Project Gutenberg are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.